Replace according to the recommended cycle in the equipment manual (typically every 1,000 - 4,000 hours), or adjust based on the oil quality monitoring results.
Installation Notes
Ensure good sealing to avoid oil leakage; drain all residual oil from the system during replacement to prevent impurities from remaining.
Filter Selection
Use original or certified filters that match the compressor model and operating conditions (special filters are required for high-temperature and dusty environments).
Fault Symptoms
Filter Blockage: Increased oil pressure, abnormal oil temperature, which may trigger the bypass valve and allow unfiltered oil to enter the system.
Filter Damage: Pollutants directly enter the lubrication system, accelerating component wear.
Seal Failure: Leakage of lubricating oil, resulting in insufficient lubrication or a decrease in system pressure.