We are glad to share with you about the results of our work, company news,and give you timely developments and personnel appointment and removal conditions.
Correlation check:
When replacing the sealing kit, simultaneously inspect the sealing surfaces of the instrument block for scratches, deformation or corrosion. If necessary, repair or replace the instrument block.
Check whether the threads of the related pipelines and sensor interfaces are in good condition to avoid poor sealing due to damaged threads.
Although this sealing kit is a small maintenance component, it is crucial to the reliability of the instrument control module.
The WSD250-750, as the original drainage component, has the best compatibility with Atlas Copco air compressors and post-treatment equipment. It can effectively prevent leakage or poor drainage problems caused by the mismatch of accessory part sizes.
Maintenance and Replacement Recommendations:
Regular Cleaning: Check and clean the filter screen weekly to remove impurities. Increase the frequency in high-humidity environments.
Seal Replacement: If there is air leakage, replace the aged O-ring or sealing gasket (it is recommended to use original factory parts) first.
Overall Replacement: When the valve body is worn out, the valve core is stuck and cannot be repaired, or the electromagnetic valve continues to malfunction, the entire automatic drainage valve assembly needs to be replaced.
Original Factory Compatibility: The interface specifications and pressure ratings of the drainage valves for different models of air compressors are different. It is necessary to select Atlas Copco original components to ensure compatibility and safety.
Correlation check:
Verify that the cooler and the lubrication system are unobstructed to prevent premature damage to the temperature control kit due to blockage by other components.
After replacement, it is recommended to shorten the initial oil change interval to ensure system cleanliness.
The normal operation of the constant temperature kit directly affects the lubrication effect and lifespan of the air compressor. When replacing it, strictly follow the technical manual of the corresponding model.
Coupling replacement: When replacing the coupling, it is recommended to simultaneously check the condition of the motor and the main machine bearings, as coupling failures may be caused by shaft displacement resulting from bearing wear.
Key points for replacement and installation:
Accessory matching: It is necessary to use the original Atlas Copco connectors to ensure that the thread specifications (such as diameter, pitch, and length) are fully compatible with the MPV end caps of the corresponding model (the MPV specifications for different series of air compressors may vary).
Sealing treatment: During installation, wrap sealing tape (such as PTFE tape) around the threads or apply sealant to ensure airtightness at the connection point and prevent leakage.
Tightening specifications: Use the appropriate tools to tighten according to the specified torque to avoid over-tightening which may cause thread slippage or end cap deformation, and under-tightening which may lead to leakage.
Interlock check: After replacement, check whether the relevant pipelines (such as the pressure sensor pipeline) are unobstructed to ensure that the pressure signal is normally transmitted to the control system.