Part Warranty:
It is mandatory to use the original Atlas Copco kit. Subpar filter elements may cause damage to the main unit due to insufficient filtration accuracy or poor material quality, and may also affect the equipment warranty.
This kit is a basic spare part for the regular maintenance of the air compressor. Strictly following the 4,000-hour replacement cycle can significantly enhance the reliability of the equipment.
Installation and Maintenance Tips:
Professional Installation: Operated by authorized technicians to ensure correct connection of the oil/gas interfaces and proper installation of the seals (especially for water-cooled models, prevent water leakage).
Cleaning and Maintenance:
Wind-cooled models: Regularly clean the surface dust and oil stains of the heat sinks (using compressed air blowing or special cleaning agents).
Water-cooled models: Regularly check the water quality to prevent scale deposition (add scale inhibitors), and conduct at least one flushing cleaning per year.
System Inspection: After replacing the cooler, check if the auxiliary components such as fans and water pumps (for water-cooled models) are functioning properly to ensure the effective Cooperation of the cooling system.
The cooler kit is the core spare part for maintaining the thermal balance of the air compressor. Choosing original factory parts can maximize the guarantee of equipment performance and safety.
Daily maintenance for the 2903102422 model V belt of Atlas Copco air compressor:
Regularly clean the oil stains on the belt surface (oil stains can cause rubber aging and slipping).
Check the tension. As the belt stretches naturally after operation, it needs to be adjusted in time.
Avoid contact of the belt with sharp objects to prevent scratches.
Although the V belt is a wear-prone part, it directly affects the normal operation of the auxiliary system of the air compressor (such as insufficient cooling may lead to excessively high oil temperature). When replacing it, strictly follow the technical manual of the corresponding model.
Correlation check:
When replacing the sealing kit, simultaneously inspect the sealing surfaces of the instrument block for scratches, deformation or corrosion. If necessary, repair or replace the instrument block.
Check whether the threads of the related pipelines and sensor interfaces are in good condition to avoid poor sealing due to damaged threads.
Although this sealing kit is a small maintenance component, it is crucial to the reliability of the instrument control module.
The WSD250-750, as the original drainage component, has the best compatibility with Atlas Copco air compressors and post-treatment equipment. It can effectively prevent leakage or poor drainage problems caused by the mismatch of accessory part sizes.
Maintenance and Replacement Recommendations:
Regular Cleaning: Check and clean the filter screen weekly to remove impurities. Increase the frequency in high-humidity environments.
Seal Replacement: If there is air leakage, replace the aged O-ring or sealing gasket (it is recommended to use original factory parts) first.
Overall Replacement: When the valve body is worn out, the valve core is stuck and cannot be repaired, or the electromagnetic valve continues to malfunction, the entire automatic drainage valve assembly needs to be replaced.
Original Factory Compatibility: The interface specifications and pressure ratings of the drainage valves for different models of air compressors are different. It is necessary to select Atlas Copco original components to ensure compatibility and safety.