1624117200 Atlas Copco Original DIFF. PRESSURE GAUGE FOR OIL INJECTED SCREW COMPRESSOR13 2025-08

1624117200 Atlas Copco Original DIFF. PRESSURE GAUGE FOR OIL INJECTED SCREW COMPRESSOR

Common Faults and Solutions of Atlas Copco Air Compressor Pressure Gauges Pointer not moving or stuck Reason: Internal gears stuck, spring tube damaged, interface blocked (impurities or condensate water frozen). Solution: Disassemble and clean, remove the blockage; replace the gauge if severely damaged. Incorrect or drifting reading Reason: Elastic element fatigue (long-term use), pointer loose, drastic changes in environmental temperature. Solution: Re-calibrate; replace aging components or pressure gauge. Shell leakage Reason: Sealing of shock-resistant gauge is poor, screws of the shell are loose. Solution: Add silicone oil / glycerin and seal; tighten the screws; replace the shell if severely damaged.
Original 1622698871 Atlas Copco Air Compressor Gear Set 8809/881013 2025-08

Original 1622698871 Atlas Copco Air Compressor Gear Set 8809/8810

Original Equipment Parts and Replacement Considerations The Atlas Copco gear set is a core component. It is recommended to preferentially use original equipment parts . The advantages of using original equipment parts are as follows: It perfectly matches the parameters of the main unit and the motor, ensuring transmission efficiency The material and processing accuracy meet strict standards, and the lifespan can reach 8-150,000 hours If alternative parts are chosen, the gear module, tooth count, tooth profile , center distance, etc. must be strictly verified to avoid operational failures due to size deviations. In summary, the Atlas Copco air compressor gear set, with its high-precision design and high-quality materials, ensures efficient transmission of the equipment. However, it is necessary to conduct regular maintenance to extend its service life and avoid the entire machine stopping due to gear failures.
Original Atlas Copco 1622550781 Thermostat 40c for oil injected screw comprssor13 2025-08

Original Atlas Copco 1622550781 Thermostat 40c for oil injected screw comprssor

Maintenance and Common Issues of 40°C Thermostat for Atlas Copco Air Compressors Regular Calibration: After long-term use, temperature drift may occur. It is recommended to calibrate with a thermometer annually to ensure accurate triggering at 40°C. Cleaning and Maintenance: If the sensing part is covered with oil or dust, it will affect the sensitivity of temperature measurement. It is necessary to wipe it regularly (operate in power-off state). Common Faults: Temperature Trigger Deviation: This may be due to the aging of the sensing element. Replacement of the same model thermostat is required. Contact Adhesion: Causes the cooling equipment to run continuously or fail to start. Check the contact condition and replace it if necessary.
Original 1622486700 Atlas Copco NIPPLE M12X1,5 X G1/4 FOR OIL INJECTED SCREW COMPRESSOR13 2025-08

Original 1622486700 Atlas Copco NIPPLE M12X1,5 X G1/4 FOR OIL INJECTED SCREW COMPRESSOR

Key Points for Bolt Installation and Maintenance of Atlas Copco Pre-tightening Torque: Appropriate torque should be applied according to the bolt's strength grade and connection requirements . Excessive torque can cause the bolt to break, while insufficient torque may result in poor sealing or loosening. Surface Treatment: The bolt surface is usually galvanized, phosphated , or oxidized . Before installation, check the surface for rust or damage. Cooperation Precision: The cooperation between the bolt and the nut or the bolt hole must comply with standards . Avoid overly loose or overly tight threads. Regular Inspection: After the air compressor has been running for a period of time, check if the bolts are loose. If rust, deformation, or fracture is found, replace the bolts of the same specification and strength in a timely manner.
1622369407 Atlas Copco Air compressor Glide Seal Part Original13 2025-08

1622369407 Atlas Copco Air compressor Glide Seal Part Original

Maintenance suggestions for the sliding sealing components of Atlas Copco air compressors: Regularly inspect the wear condition of the sealing parts (such as the opening gap of the piston ring, the leakage volume of the piston rod seal); Atlas Copco Ensure the normal operation of the lubrication system (oil mist lubrication or solid lubricant in no-oil conditions); Atlas Copco Filter the intake air (reduce dust and other impurities); When replacing the sealing parts, select the model and material that match the working conditions and ensure the installation accuracy.
Atlas Copco air Compressor Seal 161662020012 2025-08

Atlas Copco air Compressor Seal 1616620200

Although the seals of Atlas Copco are considered wear-prone parts, they are crucial for the efficient and safe operation of the air compressor. Proper selection, regular replacement, and standardized installation can effectively reduce leakage faults, lower energy consumption and maintenance costs.