Dongguan Taike Trading Co., Ltd.
Dongguan Taike Trading Co., Ltd.
Products

Products

China Z110-145 INLET VLV BRG BLOCK Manufacturer, Supplier, Factory

Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Z110-145 INLET VLV BRG BLOCK, 2906049700, Atlas Copco INLET VLV BRG BLOCK, INLET VLV BRG BLOCK, We warmly welcome all intrigued customers to speak to us for additional information and facts.
Z110-145 INLET VLV BRG BLOCK, In order to meet the increasing requirement of customers both home and aboard, we'll keep carrying forward the enterprise spirit of "Quality, Creativity, Efficiency and Credit" and strive to top the current trend and lead fashion. We warmly welcome you to visit our company and make cooperation.

Hot Products

  • 3001500567 GA90+-160(VSD) 8000 HRS KIT

    3001500567 GA90+-160(VSD) 8000 HRS KIT

    Our Atlas Copco 3001500567 GA90+-160(VSD) 8000 HRS KIT comes in one package with all the genuine parts you need for a maintenance intervention. Our Atlas Copco Wuxi Factory usually has a large amount of stock, under normal circumstances, it can be shipped directly 1-2 weeks after the order is placed.
  • Original 2230004012 Atlas Copco KIT SERVICE KIT CD5-22 CONTR VALVE

    Original 2230004012 Atlas Copco KIT SERVICE KIT CD5-22 CONTR VALVE

    Atlas Copco CD5-22 Control Valve Maintenance and Precautions Regular Inspection: Regularly check if the valve has any air leakage, jamming or pressure adjustment failure. If abnormal pressure fluctuations or slow response are detected, it may be due to aging internal seals or blockage by impurities. Cleaning and Replacement: During maintenance, the valve body can be disassembled (requiring professional operation). Clean the internal valve core and valve seat, replace the aged seals; if the valve core is severely worn, it is recommended to replace the control valve as a whole to ensure performance. Parameter Matching: When replacing, confirm that the pressure adjustment range, interface size of the new valve match the original system, to avoid control failure due to incompatible specifications.
  • 3001500623 Atlas Copco

    3001500623 Atlas Copco

    How to correctly select the "soft connection kit for flexible joints" of Atlas Copco screw air compressors Determine the position: transmission end (bevel gear) or pipeline end (quick change / flexible hose). Verify the model and serial number: Confirm the part number by referring to the service manual / nameplate, avoid cross-platform misuse. Pay attention to parameters: Transmission end - compensation capacity, torque, material; Pipeline end - diameter, pressure rating, interface standard, length. Prioritize original factory / certified products: Ensure lifespan and reliability.
  • Atlas Copco Breather Filters 1650122800

    Atlas Copco Breather Filters 1650122800

    If you are looking for Atlas Copco Breather Filters 1650122800 for your air compressors, you get to the right website. we will provide you the genuine parts for this After Cooler with best price.
  • 2901161700 Atlas Copco air compressor THERMOSTAT KIT 60 DEGREE C FOR OIL INJECTED SCREW COMPRESSOR Original

    2901161700 Atlas Copco air compressor THERMOSTAT KIT 60 DEGREE C FOR OIL INJECTED SCREW COMPRESSOR Original

    Maintenance tips for Atlas Copco air compressor thermostat kit: Regularly remove the thermostat valve for cleaning, remove foreign substances that may exist in the lubricating oil, and prevent blockage. You can put the valve core in 80℃ water to observe. If the valve core expands fully in this environment and is 10-15mm longer than at normal temperature, then the valve core is normal. If there are aging or other issues, the thermostat valve needs to be replaced.
  • 1092002335 Atlas Copco air compressor OIL FILTER HOUSING Original

    1092002335 Atlas Copco air compressor OIL FILTER HOUSING Original

    Atlas Copco Air Compressor Oil Filter Housing Selection and Replacement Precautions Compatibility: It must match the filter element model, the interface size of the unit, and the working pressure to avoid filter failure due to excessive installation gap. Certification Requirements: Preferentially choose the housing from the original manufacturer or those that have passed pressure certification (such as ASME, CE) to ensure pressure safety. Installation Specifications: During assembly, the sealing surfaces need to be cleaned, and a small amount of lubricating oil should be applied to the O-ring to avoid cracking of the housing due to overly tight screws. Although the Atlas Copco air compressor oil filter housing is an auxiliary component, its reliability directly affects the stability of the filtration system. Regularly checking the sealing performance and structural integrity of the housing is an important step in preventing oil contamination.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept