Dongguan Taike Trading Co., Ltd.
Dongguan Taike Trading Co., Ltd.
News

News

News

We are glad to share with you about the results of our work, company news,and give you timely developments and personnel appointment and removal conditions.
Atlas Copco Air Compressor 2906082800 8000 Hours Service Maintenance Kit Screw Spare Parts03 2025-09

Atlas Copco Air Compressor 2906082800 8000 Hours Service Maintenance Kit Screw Spare Parts

ATLAS COPCO "8000 Hours Service Maintenance Kit" Purchase and Replacement Key Points Verify "Model + Serial Number" to confirm the part number with the service manual and the spare parts list. Prefer original factory or certified accessories. Replace according to the steps in the service manual. Pay attention to torque, sealing, exhaust and fluid replenishment procedures. After completion, record and reset the maintenance timer. In harsh environments or high-load conditions, it can be shortened to 6000 - 7000 hours; pay attention to condensation and drain valve maintenance in humid environments. If abnormal sounds, vibrations, temperature or pressure occur after replacement, immediately shut down the machine for inspection and contact the service team.
1089065963 Replacement Water Lever Transducer for Atlas Copco Compressor03 2025-09

1089065963 Replacement Water Lever Transducer for Atlas Copco Compressor

Atlas Copco Air Compressor "Water Level Sensor" Quick Diagnosis and Common Issues False Alarm / Failure to Report: Check if the installation is loose, if the probe is clogged / blocked or covered; Calibrate or replace the sensor. Continuous Alarm: Check if the drain valve is blocked or if the control logic is abnormal; Clean the valve group and piping. Abnormal after Replacement: Verify the part number, wiring and range / upper and lower limit settings; Reset / re-calibrate if necessary.
1900520440 Atlas Copco Air Compressor Oil Temperature Electronikon Control Module02 2025-09

1900520440 Atlas Copco Air Compressor Oil Temperature Electronikon Control Module

Maintenance and Fault Handling of the Oil Temperature Electronic Elektronikon Control Module of Atlas Copco Air Compressors If there are abnormal oil temperature readings, the heating/cooling system does not respond, or the oil temperature protection is triggered frequently, it may be related to this control module. Maintenance suggestions: First, check whether the oil temperature sensor and connection lines are normal. Eliminate front-end signal faults; If the module itself is faulty, it is recommended to replace the original factory parts to ensure control performance. After replacement, calibration of parameters through special tools is required to make it match the model; Regularly check the module status through the self-check function of the Elektronikon system to promptly detect potential problems.
Atlas Copco Air Compressor Pressure Sensor 108996250102 2025-09

Atlas Copco Air Compressor Pressure Sensor 1089962501

Common Issues and Maintenance of Atlas Copco Air Compressor Pressure Sensors Common issues with pressure sensors include measurement drift (inaccurate data), signal interruption (line or component failure), interface leakage, etc. Maintenance suggestions: Regularly check the sealing of the sensor installation to avoid pressure leakage or measurement errors due to looseness; Keep the sensor interface clean to prevent oil contamination and impurities from blocking and affecting the measurement; When there is abnormal pressure display, frequent start-stop of the unit, or incorrect pressure protection operation, it is necessary to check if the sensor is faulty. It is recommended to replace the original sensor to ensure performance matching. When replacing, pay attention to keeping the calibration parameters consistent with the original model.
Atlas Copco Spare Parts 1635630500 Metal Air Compressor Solenoid Valve02 2025-09

Atlas Copco Spare Parts 1635630500 Metal Air Compressor Solenoid Valve

Common Faults and Maintenance of Electromagnetic Valves in Atlas Copco Air Compressors Common faults of electromagnetic valves include coil burnout (resulting in inability to operate), valve core sticking (caused by impurities or wear), and aging of sealing components (leading to medium leakage). During daily maintenance, the following points should be noted: Regularly check if the connection terminals are loose to avoid poor contact; Keep the valve body clean to prevent impurities from entering the valve core; When there is abnormal operation, it is recommended to replace the original electromagnetic valve to ensure performance compatibility. When replacing, pay attention to the consistency of voltage specifications and interface dimensions.
Atlas Copco Screw Air Compressor Parts 2901358100 VCU Service Kit02 2025-09

Atlas Copco Screw Air Compressor Parts 2901358100 VCU Service Kit

Maintenance and replacement instructions for the VCU (Valve Control Unit) service kit of Atlas Copco screw air compressors When the compressor experiences frequent loading/unloading, pressure out-of-control, valve sticking, or VCU leakage, it may be related to the valve control unit failure. It is recommended to use this service kit for repair. During the replacement process, follow the specifications in the equipment manual, pay attention to the correctness of electrical connections and the installation direction of sealing components, and if necessary, calibrate the control parameters to ensure that the VCU function returns to normal after the repair.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept