Different series must not be mixed: The formulations and application scenarios of Roto and Paroil are different. It is strictly prohibited to substitute across series.
Oil change requires complete replacement: When changing to different brands/formulations, it is recommended to drain the oil during warm-up → flush → replace the oil filter and oil separator → add new oil. And check the oil quality and level in a short period after the first run.
Mobile common parameters (example): Paroil S ISO VG 46, pour point approximately -57 ℃, flash point approximately 248 ℃, suitable temperature approximately -25/+30 ℃ (high pressure) to -25/+50 ℃ (low pressure), oil change approximately every 1000 hours (refer to the manual).