Attention to the Atlas Copco Adsorption Dryer Silencer:
During installation, ensure that the sealing gasket is intact to prevent air leakage, which could lead to increased noise and reduced regeneration efficiency;
Do not replace it with an incompatible model at will (for example, if the diameter is too small, it will cause excessive exhaust resistance, affecting the regeneration effect of the adsorbent);
The original factory silencer is usually designed with acoustic optimization, not only providing better noise reduction effects, but also ensuring the smoothness of the regeneration exhaust and maintaining the normal cycle of the dryer.
Application scenarios and maintenance for Atlas Copco KIT THERM MPV C40
Applicable models for Atlas Copco KIT THERM MPV C40: Mostly used in medium-sized oil-lubricated screw compressors of Atlas Copco (such as some models of the GA series), especially suitable for working conditions with high requirements for pressure stability and oil-gas separation efficiency (such as precision manufacturing, food and pharmaceutical industries).
Maintenance points:
Atlas Copco KIT THERM MPV C40: Regularly check for any leakage in the valves (judged by the rate of pressure drop);
Clean the valve cores and sealing surfaces to avoid jamming caused by oil stains and impurities;
If the temperature sensing element fails, it needs to be replaced in time to maintain the constant temperature control function.
ATLAS COPCO GA160 Operating Instructions
Before operation, please read the equipment manual to avoid mistakenly modifying critical parameters (such as excessive pressure limit).
When a red fault alarm occurs, stop the machine for inspection first, eliminate the fault, and then restart it.
Regularly clean the control panel to prevent dust or oil stains from affecting the sensitivity of the buttons.
Attention points for pressure reducers in Atlas Copco air compressor systems:
Matching system pressure: The rated input pressure of the pressure reducer must match the exhaust pressure of the air compressor (for example, if the rated pressure of the air compressor is 10 bar, a pressure reducer with a rated input of ≥ 10 bar should be selected).
Downstream load limit: The output pressure should be set according to the rated working pressure of the downstream equipment to avoid overpressure damage to the equipment.
Regular calibration: After long-term use, pressure drift may occur, so it is necessary to regularly check and calibrate to ensure stable pressure.
The component design of Atlas Copco dryers emphasizes compatibility with air compressor systems. By optimizing heat exchange efficiency, adsorbent performance and automatic control logic, it achieves low energy consumption and high stability in the drying process of compressed air.
Atlas Copco Air Compressor Oil Check Valve Maintenance and Replacement
Check Period: It is recommended to conduct checks every 1-2 years or in accordance with the equipment manual (for example, after 4000-8000 hours of operation), and perform the checks simultaneously when replacing the filter and oil.
Maintenance Points:
Clean the valve core and valve seat to remove impurities;
Check the wear of the seals and replace them promptly if they are aged;
Test the elasticity of the springs. If the elasticity is insufficient, replace the entire valve.
Replacement Precautions:
Select original factory parts that match the model (such as Atlas Copco, Ingersoll Rand, etc. have dedicated oil check valves). Ensure that the size and pressure parameters are consistent;
Pay attention to the direction during installation, and avoid installing it in the wrong direction;
After replacement, start the equipment and check if the oil circuit pressure is normal and if there is any leakage.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.