Dongguan Taike Trading Co., Ltd.
Dongguan Taike Trading Co., Ltd.
News

News

Industry News

1092002335 Atlas Copco air compressor OIL FILTER HOUSING Original14 2025-08

1092002335 Atlas Copco air compressor OIL FILTER HOUSING Original

Atlas Copco Air Compressor Oil Filter Housing Selection and Replacement Precautions Compatibility: It must match the filter element model, the interface size of the unit, and the working pressure to avoid filter failure due to excessive installation gap. Certification Requirements: Preferentially choose the housing from the original manufacturer or those that have passed pressure certification (such as ASME, CE) to ensure pressure safety. Installation Specifications: During assembly, the sealing surfaces need to be cleaned, and a small amount of lubricating oil should be applied to the O-ring to avoid cracking of the housing due to overly tight screws. Although the Atlas Copco air compressor oil filter housing is an auxiliary component, its reliability directly affects the stability of the filtration system. Regularly checking the sealing performance and structural integrity of the housing is an important step in preventing oil contamination.
1613610590 Atlas Copco air compressor FILTER OIL Original14 2025-08

1613610590 Atlas Copco air compressor FILTER OIL Original

Maintenance recommendations for the oil filter of Atlas Copco screw air compressors: Replacement cycle: Under normal operating conditions, replace the filter once every 2,000 - 3,000 hours. In harsh environments (such as high dust and high temperature), this period should be shortened to 1,500 hours. Synchronous operation: When replacing the filter element, also simultaneously discharge the settled oil at the bottom of the oil tank (containing a large amount of impurities) and refill the oil to the specified level. Selection requirements: It is necessary to select original factory or certified filter elements that match the compressor model to avoid equipment damage due to size mismatch or insufficient filtration accuracy. Effective maintenance of the oil filter can significantly reduce the wear rate of the screw main unit and is a key aspect of the daily maintenance of the compressor unit with low cost and high efficiency.
Original 1621938400 & 2901905600 Atlas Copco Screw air compressor Oil Separator parts14 2025-08

Original 1621938400 & 2901905600 Atlas Copco Screw air compressor Oil Separator parts

Common Problems and Maintenance of Atlas Copco Oil Separator Reduced separation effect Reason: Filter blockage, damage, poor return oil pipeline, or excessively high temperature of the oil-gas mixture . Solution: Replace the filter, clean the return oil pipe, and check the cooling system to ensure the exhaust temperature is normal . Excessive pressure difference Sign: The pressure difference between the separator inlet and outlet exceeds 0.15MPa, resulting in reduced exhaust volume and increased energy consumption. Solution: Replace the filter in time to avoid filter damage or overload of the housing due to excessive pressure difference. Return oil failure Reason: Return oil valve blockage, throttling hole blockage, or leakage of the return oil pipe. Harm: The compressor operates without oil, causing wear of the main unit and sudden temperature rise. Solution: Disassemble and clean the return oil components to ensure smooth return oil.
2901186400 Atlas Copco Screw Air compressor Check Valve Kit Original14 2025-08

2901186400 Atlas Copco Screw Air compressor Check Valve Kit Original

Atlas Copco Check Valve Kit Common Faults and Maintenance Leakage: This is often caused by worn sealing surfaces, debris blocking, or failed springs. It requires disassembly for cleaning, grinding the sealing surfaces, or replacing the components. Stalling: Oil and impurities in the compressed air may cause the valve core to get stuck. Regular checks and cleanings should be conducted, and air filters should be maintained more frequently. Strange noises: Collisions between the valve core and the valve seat or loose springs may produce noises. The tightness of the components and wear conditions should be checked. Regularly (suggested every 2000-3000 hours of operation) inspecting, cleaning, and conducting performance tests on the check valve assembly of Atlas Copco Check Valve Kit is an important measure to ensure the efficient operation of screw machines.
Atlas Copco air compressor DD60 oil coalescing filters Original14 2025-08

Atlas Copco air compressor DD60 oil coalescing filters Original

The Atlas Copco DD60 oil coalescing filter is a crucial equipment for upgrading the quality of compressed air, especially indispensable in scenarios with high cleanliness requirements. During daily use, proper maintenance and timely replacement of the filter element are the core to ensuring its long-term efficient operation. It is recommended to strictly follow the maintenance guidelines in the equipment manual.
1619756000 Atlas Copco air compressor THERMOSTAT 40°C Original parts14 2025-08

1619756000 Atlas Copco air compressor THERMOSTAT 40°C Original parts

Atlas Copco Operating Instructions The 40°C setting value for Atlas Copco is an optimized parameter specific to certain models or working conditions. It cannot be adjusted at will. Otherwise, it may affect the temperature control accuracy, leading to reduced equipment operation efficiency or component damage. When replacing parts, choose Atlas Copco original accessories to ensure they match the temperature control logic and interface of the equipment. Avoid system failures caused by compatibility issues. For specific model compatibility or more detailed technical parameters, it is recommended to refer to the equipment manual or contact the Atlas Copco authorized service center for confirmation.